Wireless Room Thermostat (B) Exclude

This article is an excerpt from the Genius Hub Doctor, which is built into the App.

These instructions are provided so that the step-by-step information is available to users, but please note that these actions should generally be carried out whilst using the Doctor.

To access the Doctor, click here

Solution ID: 7652

Step 1

The the Wireless Room Thermostat to the same room as the Genius Hub.

Remove the thermostat from its backplate by loosening the two screws at the bottom of the backplate.

Ensure there are working batteries in the Room Thermostat.

Turn the thermostat over, so the dial is facing away from you and put the number 1 dip switch (left side) into the UP (on) position.


Step 2

Now the Genius Hub needs to get ready to remove the device.

The Doctor will remove the device


Step 3

Turn the thermostat back over so the dial is facing you.

Rotate the dial until 'L' is on the screen and press the dial, as a button. 'L' will start to flash.

After 10 seconds the screen shows 'LP' when the device has excluded successfully.

If 'LP' is not displayed this is not a problem so long as a number for the device is included successfully in the status box below.


The Doctor will communicate with the device


Step 4

Turn the thermostat over, so the dial is facing away from you and put the number 1 dip switch into the DOWN (off) position.