The Genius Hub system can control a wide variety of wet underfloor heating, both in terms of the configuration of the underfloor heating, the floor covering and the hardware that is already part of the underfloor heating system. It can also control electric underfloor heating with the Powered Room Thermostat.

Info

Standard wiring diagrams are provided with the system. To download a copy of the wiring diagrams, visit: https://www.geniushub.co.uk/wiring

All devices which control the heating in individual rooms and are purchased as part of a system direct from Genius Hub, such as Underfloor Receiver Units, Genius Radiator Valves or Room Sensors, are labelled with the room they control and are pre-linked to zones on the app.

Powered Room Thermostat (Switched Live connections, or Single Zone / Underfloor Pump, Electric Underfloor)

Image Added

If you are controlling an underfloor heating wiring centre or actuators which are 230v the Electric Switch will be used per zone controlled. If there are any existing controls, such as a thermostat the wiring to these will need to be removed. The Electric Switch is often wired near the actuators / wiring centre and the Room Sensor or Room Thermostat placed in the room with the underfloor heating. 

If you are only controlling a single zone of underfloor heating, you are likely to need to switch the underfloor circulation pump directly from the controller along with any zone valves or actuators. The Electric Switch is to be used in these situations.

  1. The Powered Room Thermostat fits into a standard 1-gang pattress, we recommend approximately 40mm deep.
    1. If you are using a flush mount pattress it should screw in without any problems.
    2. If you are using a surface mount pattress, you may need to use the 2 spacers to bring the Powered Room Thermostat closer to the edge of the pattress.
  2. Wire in the temperature probe or link into the 'Floor Sensor' terminals.
    Image Added
  3. Install the pattress into the room the Powered Room Thermostat is going to control.
    1. If using the floor probe, consider how this is going to get out of the pattress and it is going to be installed into the floor layer/onto the pipework of the wet underfloor.
  4. Wire in the mains power and the heating load to the Powered Room Thermostat.
  5. To screw the Powered Room Thermostat to the pattress, first remove the screen by pushing a small flat-bladed screwdriver into the flat gap on each side of the screen. This will release the 2 spring clamps, and the screen and frame will become loose.
    Image Added
  6. Screw the Powered Room Thermostat to the pattress. Due to the cutouts to the side of the screen of the PRT, it can either be screwed directly to the pattress, or the screws can be mostly screwed in first and the Powered Room Thermostat placed over the screwheads and rotated.
    1. See 1.b if using a surface mount pattress.
      Image Added
  7. Place the frame on the Powered Room Thermostat and push the screen in place to secure the two parts to the main unit. 
  8. If using the Floor Prove, fit this into the floor layer before powering using the Powered Room Thermostat.

In normal operation there will be no lights when the unit is off and one red light to the bottom-right of the display when heating.

Electric Switch (Switched Live connections, or Single Zone / Underfloor Pump)

...

  1. Always ensure that the boiler, underfloor heating and wiring for the Electric Switch is electrically isolated before you commence work on any wiring.
  2. Break out the relevant section of a 1-gang pattress for the wiring and fix the pattress to the wall. It is recommended that a 40mm pattress is used.
  3. Pull through the relevant wiring, allowing plenty of spare.
  4. Remove the front cover of the Electric Switch by placing a screwdriver in the slot under the device and levering the cover forwards.
    Image Added
  5. Wire in the Electric Switch as per the wiring diagrams provided, checking this is suitable as per the relevant installation manuals.
  6. Fit the Electric Switch into the pattress, ensuring there are no trapped wires. Screw in using standard pattress screws (provided), and check the unit is securely and safely attached to the wall.
  7. Reattach the front cover, starting at the top.

In normal operation there will be no lights when the unit is off and one or more red lights near the button when heating.

Electric Relay (Low Voltage/Volt free connections or Switched Live connections)

...

  1. Always ensure that the boiler, underfloor heating and wiring for the Electric Relay is electrically isolated before you commence work on any wiring.
  2. Break out the relevant section of a 1-gang pattress for the wiring and fix the pattress to the wall. It is recommended that a 40mm pattress is used.
  3. Pull through the relevant wiring, allowing plenty of spare.
  4. Wire in the Electric Relay as per the wiring diagrams provided, checking this is suitable as per the relevant installation manuals.
  5. Fit the Electric Relay into the pattress, ensuring there are no trapped wires, fit the blanking plate to the front of the pattress. Screw in using standard pattress screws, and check the unit is securely and safely attached to the wall.
    Image Added

Pagebreak

Single Channel Receiver (Low Voltage/Volt free connections)

...

In normal operation the Single Channel Receiver will have a single solid light (red for when there is no call for heat, and green for when the Receiver unit is is calling for heat).

...

General Information

The Single Channel Receiver is rated to 3A maximum. It can only be used to switch a zone valve, underfloor heating wiring centre or actuator and not a circulation pump. Controlling a circulation pump will result in damaging the receiver units, voiding the warranty! The Electric Relay is rated to 11A maximum. The Electric Switch is rated to 13A maximum.

...