This product complies with the requirements of European Directives 2006/95/EC, 2004/108/EC and 1999/5/EC.
...
Info |
---|
Full specifications can be downloaded from: https://www.geniushub.co.uk/wiring |
Operating Environment: Operating the Genius Devices outside these ranges may affect performance:
- Transmission Frequency: 868.42 (EU) MHz
- Relative humidity: 10% to 85% (noncondensing)
- Operating altitude: 0 to 3048 meters (0 to 10,000 feet)
- Indoor User Only
- RoHS Compliant
Transmitting Frequency: All devices communicate on 868.42 (EU) MHz.
Genius Hub specifications:
- Line Voltage: 5V DC (USB)
- Current: 2A Max. (10W)
- Line Voltage: 100-240V AC
- Regulation: EN 55022:2010 + AC:2011, EN 55024:2010, EN 61000-3-2:2006+A2:2009, EN 61000-3-3:2013
Single Channel Receiver specifications:
- Frequency: 50-60Hz, single phase
- Line Voltage: 230V AC
- Contact Type: Micro disconnection voltage free
- Contact Rating: 3 (1) A 230V AC Max.
- Rated impulse voltage: CAT 2 - 2500V
- Enclosure Protection: IP30
- Regulation: EMC 2004/108/EC, R&TTE 1999/5/EC, LDV 2006/95/EC
Dual Channel Receiver specifications:
- Frequency: 50-60Hz, single phase
- Line Voltage: 230V AC
- Contact Rating: 3 (1) A 230V AC Max.
- Rated impulse voltage: CAT 2 - 2500V
- Enclosure Protection: IP30
- Regulation: EMC 2004/108/EC, R&TTE 1999/5/EC, LDV 2006/95/EC
Electric Switch specifications:
- Frequency: 50-60Hz, single phase
- Line Voltage: 230V AC
- Contact Rating: 13A resistive / 3A inductive 230V AC, suitable for loads up to 3kW
- Contact Type: Micro disconnection
- Rated impulse voltage: CAT 2 - 2500V
- Enclosure Protection: IP30
- Regulation: EN 60730-2-7, CE, R&TTE, ETSI EN 300 220-2, ETSI EN 301 489-3
Smart Plug specifications:
- Frequency: 50Hz, single phase
- Line Voltage: 220V - 230V AC
- Resistive Load: 3000W
- Incandescent Load: 1500W
- Fluorescent Load: 320W
- Load Return Error Rate 5W~40W:±3W
- Load Return Error Rate 40W~3150W:±5%
- Overload: 3300W
- Regulation: LVDEN 61058, R&TTEEN 301489, EN 300200
Thermostat specifications:
- Power Supply: 3 x AA alkaline batteries
- Temperature Range 5oC - 30oC
- Enclosure Protection: IP21
- Regulation: EN 62479:2010, EN 62368-1:2014+A11:2017
Radiator Valve specifications:
- Power Supply: 2 x AA alkaline batteries
- Mechanical Strength: 70 N (max. force from valve)
- Maximum Water Temperature: 90°C
- Enclosure Protection: IP20
- Spindle Movement: 2-3 mm on the valve
- Regulation: EN 60730-1, EN 60730-2-9 and EN60730-2-14
Pagebreak
Room Sensor specifications:
- Power Supply: CR123A lithium battery (1500mAh)
- Range: Front = 10m, +/- 45o = 8m
- Regulation: EN60950-1:2006, A11:2009, FCC part 15.249, EN300 220-1
Motion Sensor specifications:
- Power Supply: CR123A lithium battery (1500mAh)
- Detection Range: Front = 10m, +/- 45º = 6m
- Regulation: EN60950-1:2006, A11:2009, FCC part 15.249, EN300 220-1
Electric Relay specifications:
- Power Frequency: 50-60Hz, single phase
- Line Voltage: 230V AC
- Contact Type: Micro disconnection
- Resistive Load: 11A (2400W)
- Regulation: FCC part15.249, EN 300 220-1, NCC
Powered Room Thermostat specifications:
- Power Frequency: 50-60Hz, single phase
- Line Voltage: 230V AC
- Contact Type: Micro disconnection
- Resistive Load: 16A (3600W)
- Inductive Load: 3A (750W)
- Enclosure Protection: IP21